Antibody Raw Material · OEM Ready

H-FABP Antibody Pair

Heart-Type Fatty Acid Binding Protein Antibody for Early Cardiac AMI Diagnosis & POCT Development

CLIA LFA / POCT Earliest AMI Biomarker Humanized Clone Available Cardiac Emergency Panel
4
H-FABP SKUs Available
>90%
Purity by SEC-HPLC
30 min
Earliest AMI Rise Time
1 mg
Minimum Order Quantity

What is H-FABP? — A Definition for IVD Developers

Heart-type Fatty Acid Binding Protein (H-FABP), also designated FABP3, is a 15 kDa cytoplasmic protein expressed at high concentration in cardiomyocytes and, to a lesser degree, in skeletal muscle and brain tissue. H-FABP's primary function is intracellular long-chain fatty acid transport — carrying fatty acids from the sarcolemma to mitochondria for beta-oxidation, which provides ~70% of myocardial energy. H-FABP constitutes approximately 5% of total cytoplasmic protein in cardiomyocytes, making it one of the most abundant myocardial proteins.

For IVD assay development, H-FABP is clinically significant as the earliest cardiac biomarker for acute myocardial infarction (AMI). Due to its small size (15 kDa vs 24 kDa for Myoglobin, 23 kDa for cTnI), H-FABP enters the bloodstream within 30 minutes to 3 hours of myocardial injury onset — achieving peak serum concentration at 4–8 hours and returning to baseline within 24 hours. This early-rise, early-washout profile complements cTnI (which rises later but remains elevated for 7–14 days), making H-FABP particularly useful for:

  • Early AMI rule-in in the 0–3 hour window when cTnI may still be negative
  • Re-infarction detection within 24 hours of a first event
  • Multi-marker cardiac panel (H-FABP + cTnI + CK-MB) for comprehensive ACS assessment

Sekbio supplies a complete H-FABP antibody panel — mouse capture (S01-FABP-1M), humanized detection (S01-FABP-2H), mouse detection (S01-FABP-2M), and recombinant H-FABP antigen (S01-FABP-1) — validated for CLIA and LFA formats.

Earliest AMI Biomarker Cardiac POCT Panel ISO 13485 Manufacturer Humanized Clone Available

Antibody Specifications (S01-FABP-1M)

Product NameMouse Anti-H-FABP mAb (Capture)
Catalog No.S01-FABP-1M
Host SpeciesMouse
FormatPurified, Liquid
Purity>90% (SEC-HPLC)
Buffer20 mM PB, 150 mM NaCl, pH 7.4
Storage+2°C to +8°C (short); −20°C (long)
Shelf Life3 years
PlatformsCLIA / LFA

H-FABP Antibody Panel — All SKUs

Mouse and humanized detection antibodies plus recombinant antigen for complete H-FABP immunoassay development.

Catalog No.Product NameFormat / SpeciesPurityIntended UseStorage
S01-FABP-1MMouse Anti-H-FABP/FABP3 mAb (Capture)Mouse IgG>90% SEC-HPLCCapture — CLIA, LFA+2°C to +8°C
S01-FABP-2HHumanized Anti-H-FABP/FABP3 mAb (Detection)Humanized IgG>90% SEC-HPLCDetection — CLIA, LFA+2°C to +8°C
S01-FABP-2MMouse Anti-H-FABP/FABP3 mAb (Detection)Mouse IgG>90% SEC-HPLCDetection — CLIA, LFA+2°C to +8°C
S01-FABP-1Recombinant H-FABP/FABP3 AntigenRecombinant (E. coli)>80% SDS-PAGECalibrator / Positive Control−20°C ±2°C

MOQ 1 mg. OEM quantities (10 mg–gram scale) available. Contact info@sekbio.com for bulk pricing and current lot availability.

Performance Advantages for Cardiac POCT Development

Designed for the speed and sensitivity required in emergency AMI diagnosis and point-of-care cardiac biomarker panel development.

Earliest AMI Biomarker Available

H-FABP is detectable in serum as early as 30 minutes after myocardial injury — 1–2 hours before cTnI elevation and 2–3 hours before cTnT in conventional assays. This early window is critical for AMI rule-in in emergency triage, enabling earlier treatment decisions and better patient outcomes in the 0–3 hour presentation window.

Humanized Detection Antibody (S01-FABP-2H)

S01-FABP-2H is a humanized anti-H-FABP antibody combining a human IgG constant domain with mouse variable regions. The humanized format reduces anti-mouse background in assay formats and is preferred for platforms using human Fc-based secondary detection or when assay specificity for cardiac H-FABP over skeletal muscle FABP is critical.

CLIA & LFA Dual-Platform Validated

All H-FABP antibodies are validated for both quantitative CLIA analyzer formats and lateral flow POCT rapid test formats. H-FABP POCT lateral flow assays provide semi-quantitative or quantitative H-FABP results within 10–15 minutes — ideal for emergency department triage and pre-hospital AMI assessment.

Recombinant Antigen for Calibration

S01-FABP-1 recombinant H-FABP antigen (E. coli expression) provides a defined calibrator material for assay development and kit quality control. Using a recombinant antigen ensures consistent and reproducible calibration curve preparation independent of variable native H-FABP purification yield.

Multi-Marker Cardiac Panel Compatible

H-FABP is designed for use in multi-marker cardiac panels alongside cTnI and CK-MB. Sekbio supplies all three cardiac biomarker antibody pairs — enabling a single-supplier solution for complete cardiac emergency panel raw material. Contact info@sekbio.com for combined cardiac panel quotes and technical guidance.

ISO 13485 OEM Supply Chain

ISO 13485-compliant manufacturing in Shenzhen, China. MOQ 1 mg for R&D; gram-scale production supply for OEM manufacturing. Supports CE, NMPA, and FDA regulatory submissions. Three-year shelf life from manufacturing date with full COA provided per lot.

H-FABP Antibody Applications in IVD Development

H-FABP antibody panel for cardiac emergency diagnostics, AMI rule-in, and POCT kit development.

Early AMI Diagnosis in Emergency Department

In patients presenting with chest pain, the 0–3 hour window is critical: cTnI and cTnT may be negative within the first 1–2 hours of symptom onset, creating a diagnostic gap. H-FABP rises within 30–60 minutes of AMI onset and achieves positive detection at 3 hours in >90% of confirmed AMI cases. H-FABP POCT assays using Sekbio antibodies support early AMI rule-in during this critical window, enabling faster treatment decisions and reduced time to reperfusion therapy.

Re-infarction Detection Within 24 Hours

Following an initial AMI, cardiac troponin remains elevated for 7–14 days, making it unreliable for detecting re-infarction. H-FABP's 24-hour washout kinetics restore baseline levels rapidly, making a new H-FABP elevation after baseline normalisation a sensitive indicator of recurrent myocardial injury. Serial H-FABP measurement in the 24 hours after primary AMI treatment supports re-infarction surveillance in high-risk patients in coronary care units.

Multi-Marker Cardiac Emergency Panel

The three-marker cardiac panel (H-FABP + cTnI + CK-MB) provides superior diagnostic performance over any single marker for early ACS assessment. H-FABP provides sensitivity in the 0–3 hour window; cTnI provides high specificity from 3–24 hours; CK-MB enables re-infarction detection. Sekbio supplies all three antibody pairs for complete cardiac panel lateral flow strip or CLIA analyzer kit development — from a single ISO 13485 certified supplier.

POCT Cardiac Strip & OEM Kit Development

H-FABP POCT lateral flow rapid tests are high-demand IVD products in emergency medicine, ambulance services, and primary care. Quantitative fluorescent H-FABP POCT assays using Sekbio S01-FABP-1M and S01-FABP-2H/2M antibodies deliver results in <15 minutes from whole blood or serum. OEM rapid test manufacturers can integrate Sekbio's antibody panel with ISO 13485-compliant batch data for CE and NMPA submissions. Visit our Products page for related cardiac biomarkers, or contact our team.

Frequently Asked Questions — H-FABP Antibody Pair

Technical and commercial questions from IVD R&D engineers and procurement teams.

What is H-FABP and what is its advantage over cTnI as an early cardiac marker?

H-FABP (Heart-type Fatty Acid Binding Protein, FABP3) is a 15 kDa cytoplasmic protein that constitutes ~5% of cardiomyocyte cytoplasmic protein. Its small size enables rapid diffusion into circulation — rising within 30 minutes to 3 hours of AMI onset, 1–2 hours before cTnI. This early detection window is H-FABP's primary clinical advantage: it enables AMI rule-in when cTnI is still negative, improving diagnostic accuracy in the critical first 3 hours after chest pain onset.

What catalog numbers are in Sekbio's H-FABP product range?

Sekbio supplies: S01-FABP-1M (mouse capture antibody, purity >90% SEC-HPLC), S01-FABP-2H (humanized detection antibody), S01-FABP-2M (mouse detection antibody), and S01-FABP-1 (recombinant H-FABP antigen for calibrators). All available from MOQ 1 mg with Certificate of Analysis.

Which IVD platforms are Sekbio H-FABP antibodies validated for?

All H-FABP antibodies are validated for CLIA (quantitative chemiluminescence immunoassay) and LFA (lateral flow assay/POCT rapid test) sandwich formats. H-FABP POCT is primarily developed for emergency department triage with result turnaround <15 minutes from whole blood or serum.

What is the clinical cutoff for H-FABP in AMI diagnosis?

The commonly used clinical H-FABP cutoff for AMI is >6 ng/mL in serum at presentation. At this threshold, H-FABP provides sensitivity of 80–95% within the first 3 hours of AMI onset, superior to cTnI in this early window. H-FABP returns to baseline within 24 hours, enabling re-infarction detection. Clinical sensitivity and specificity values depend on the specific assay format and population.

What are the storage conditions and MOQ for H-FABP antibodies?

MOQ is 1 mg for R&D evaluation; OEM production quantities from 10 mg to gram scale available. S01-FABP-1M, -2H, -2M antibodies: +2°C to +8°C short-term; −20°C long-term. Avoid repeated freeze/thaw cycles. S01-FABP-1 antigen: −20°C ±2°C. Shelf life: 3 years from manufacturing date.

Can Sekbio supply complete cardiac panel antibodies for multi-marker POCT strip development?

Yes. Sekbio supplies antibody pairs for H-FABP (S01-FABP series), cTnI, and CK-MB — enabling development of a complete three-marker cardiac emergency panel from one ISO 13485 certified supplier. Combined panel antibody packages are available for LFA strip and CLIA analyzer kit development. Contact info@sekbio.com for cardiac panel quotes, or visit our Platforms page for antibody development services.

Ready to Develop Your H-FABP Cardiac Assay?

Request the full technical datasheet, cardiac panel antibody specifications, or discuss OEM supply with our team.

Guangming District, Shenzhen, China